ELECTRICAL RESISTANCE HEATING WIRES

Brand Owner (click to sort) Address Description
ELEKTRA ELEKTRA WLODZIMIERZ NYC WITOLD NYC SPOLKA JAWNA Ul. Marynarska 14 Warsaw 02-674 Poland Electrical resistance heating wires and electrical controllers therefor;The color blue appears in the wording ELEKTRA and the portion of the square and the quarter circle is yellow.;The color(s) blue and yellow is/are claimed as a feature of the mark.;
ELEKTRA Ideal Heating 216 Springfield Ave Westfield NJ 07090 Electrical resistance heating wires and electrical controllers therefor;The color blue appears in the wording ELEKTRA and the portion of the square and the quarter circle is yellow.;The color(s) blue and yellow is/are claimed as a feature of the mark.;
EMISSIONZERO CHROMALOX, INC. 103 Gamma Drive Pittsburgh PA 15238 Electrical resistance heating wires and electrical controllers therefor; Mineral insulated electric cables; Electromechanical controls for use in heating and power control installations; Thermostats; Temperature sensors; Power controllers;Installation and maintenance services for electrical heating units;E MISSION ZERO;Electric heating units and electric heaters, namely, strip heaters, over the side heaters, flange heaters, ring heaters, flexible heaters, band heaters, nozzle heaters, cartridge heaters, screwplug heaters, tubular heaters, radiant heaters, industrial air heaters, boilers for heating installations and steam generators, circulation heaters, fluid superheaters principally for industrial purposes, fluid pre-heaters principally for industrial purposes, tank heaters, liquid heaters, immersion heaters, and electric heating elements, electrical heat trace cables, electrical heat trace tape;Engineering services;
FLOORIZWARM Heatwave Systems 4137 South 500 West Murray UT 84123 Electrical resistance heating wires and electrical controllers therefor;FLOOR IS WARM;
RADIANT 8 Heatwave Systems, LC 4137 South 500 West Murray UT 84123 Electrical resistance heating wires and electrical controllers therefor;RADIANT EIGHT;RADIANT;
RADIANT SURFACES Howard, Truman O. 186 Golden Ridge Road Alamo CA 94507 Electrical resistance heating wires and electrical controllers therefor;
SECURE COMFORT E & E CO., LTD. 45875 NORTHPORT LOOP EAST FREMONT CA 94538 Electrical resistance heating wires and electrical controllers therefor;Electric blankets for household purposes;
ZOPPAS INDUSTRIES I.R.C.A. S.P.A., INDUSTRIA RESISTENZE CORAZZATE E AFFINI Via Caduti del Lavoro 3 I-31029 Vittorio Veneto (TV) Italy Electrical resistance heating wires; electrical resistors; electrical resistance heating wires for heating cables; electrical resistance heating wires for cartridge heaters; electrical resistance heating wires for tubular heaters; electrical resistance heating wires for finned heaters; electrical resistance heating wires for flexible heating elements; electrical resistance heating wires for microcoil heaters; electrical resistance heating wires for blank wire heaters; electrical resistance heating wires for aluminium tubular heaters; electrical resistance heating wires for aluminium foil heaters; electrical resistance heating wires for band heaters; electrical resistance heating wires for industrial heating systems; electrical resistance heating wires for thick film heaters; electrical resistance heating wires for radiant heater-glass ceramic hob;Steam generators being parts of machines; boilers being parts of machines;Electrical Heating cables; special electric space heaters; tubular electric space heaters; finned electric space heaters; flexible heating elements; microcoil electric space heaters; blank wire electric space heaters; aluminium tubular electric space heaters; aluminium foil electric space heaters; industrial indoor radiant heating systems, industrial heating systems comprised primarily of heating units for industrial purposes; parts of central heating radiators, namely, radiant heater-glass ceramic hob; steam generators; electric boilers, industrial boilers, heating boilers; cartridge, band and thick film heating units for industrial purposes;INDUSTRIES;
ZOPPAS INDUSTRIES ZOPPAS INDUSTRIES S.P.A. Viale Venezia, 31 I-31020 SAN VENDEMIANO (TV) Italy Electrical resistance heating wires; electrical resistors; electrical resistance heating wires for heating cables; electrical resistance heating wires for cartridge heaters; electrical resistance heating wires for tubular heaters; electrical resistance heating wires for finned heaters; electrical resistance heating wires for flexible heating elements; electrical resistance heating wires for microcoil heaters; electrical resistance heating wires for blank wire heaters; electrical resistance heating wires for aluminium tubular heaters; electrical resistance heating wires for aluminium foil heaters; electrical resistance heating wires for band heaters; electrical resistance heating wires for industrial heating systems; electrical resistance heating wires for thick film heaters; electrical resistance heating wires for radiant heater-glass ceramic hob;Steam generators being parts of machines; boilers being parts of machines;Electrical Heating cables; special electric space heaters; tubular electric space heaters; finned electric space heaters; flexible heating elements; microcoil electric space heaters; blank wire electric space heaters; aluminium tubular electric space heaters; aluminium foil electric space heaters; industrial indoor radiant heating systems, industrial heating systems comprised primarily of heating units for industrial purposes; parts of central heating radiators, namely, radiant heater-glass ceramic hob; steam generators; electric boilers, industrial boilers, heating boilers; cartridge, band and thick film heating units for industrial purposes;INDUSTRIES;
 

Where the owner name is not linked, that owner no longer owns the brand

   
Technical Examples
  1. A thermal flow sensor which is fabricated at a low cost and has improved reliability. Over a cavity (7) formed in a semiconductor substrate (2), at least a heating resistance (4) is formed near the center of the cavity with an electrical insulation film interposed between the heating resistance and the cavity. The temperature (Th) of the heating resistance (4) is controlled to be higher than the medium temperature (Ta) by a constant temperature (?Th=Th?Ta). A distance (Ws) in the direction of airflow from an upstream end of the heating resistance (4) to an upstream end of the electrical insulation film lying over the cavity and the constant temperature (?Th) satisfy the following relationship: