LIGHT THERAPY DEVICES

Brand Owner (click to sort) Address Description
BRIGHT HomeoLux 2 West 57th St., 18th Floor New York NY 10019 Light therapy devices, namely, an electronic light therapy apparatus for light pulsing at gamma frequencies (40Hz) to maintain healthy brain activity, enhancing performance in areas like memory, attention, cognition, and coordination;Light therapy devices, namely, an electronic light therapy apparatus for light pulsing at gamma frequencies (40Hz) to maintain healthy brain activity, enhancing performance in areas like memory, attention, cognition, and coordination;
DAYBREAK APOLLO LIGHT SYSTEMS, INC. 947 SOUTH 500 EAST, SUITE 210 AMERICAN FORK UT 84003 Light therapy devices, namely, light therapy lamps, portable light emitting diode devices, programmable light emitting diode devices and light therapy light boxes for providing therapeutic light to simulate dawn light and variations, dusk light and variations, and/or moon light and variations;
NEUROCEP Neuro Therapy Solutions 6509 Ladera Brisa San Clemente CA 92673 Light therapy devices, namely, infrared and visible light emitting diodes for therapeutic purposes being medical treatment;
SLEEP BETTER. WAKE REFRESHED. HAVE MORE ENERGY. IMPROVE YOUR MOOD. APOLLO LIGHT SYSTEMS, INC. 947 SOUTH 500 EAST, SUITE 210 AMERICAN FORK UT 84003 Light therapy devices, namely, sensory light therapy units for providing therapeutic light to simulate dawn light and variations, dusk light and variations, and/or moon light and variations;
WAKE TO YOUR OWN PERSONAL SUNRISE APOLLO LIGHT SYSTEMS, INC. 947 SOUTH 500 EAST, SUITE 210 AMERICAN FORK UT 84003 Light therapy devices, namely, sensory light therapy units for providing therapeutic light to simulate dawn light and variations, dusk light and variations, and/or moon light and variations;
 

Where the owner name is not linked, that owner no longer owns the brand

   
Technical Examples
  1. Cardiac treatment methods and devices providing templates representative of past tachyarrythmia events, each template associated with a therapy. A cardiac waveform is detected, and if it corresponds to a particular template associated with a previous therapy that was satisfactory in terminating a past event, the previous therapy is delivered again. If unsatisfactory, the previous therapy is eliminated as an option. If, for example, the previous therapy was an antitachycardia pacing therapy unsatisfactory in terminating the past tachyarrythmia event, delivery of the antitachycardia pacing therapy is eliminated as an option. Instead of ATP therapy, one or more of a cardioversion, defibrillation, or alternate anti-tachycardia pacing therapy may be associated with the particular template. Cardiac waveforms and templates may correspond in terms of one or more of morphology, timing, drug regimen, medication, neural activity, patient activity, hemodynamic status, cardiac tissue impedance, transthoracic impedance, or other information corresponding to the episode.