OPTICAL COHERENCE TOMOGRAPHY SOFTWARE

Brand Owner (click to sort) Address Description
APTIVUE St. Jude Medical One St. Jude Medical Drive St. Paul MN 55117 Optical coherence tomography software for medical imaging; computer software for use in medical diagnosis, namely, for use in measurement and assessment of measured physiological variables;
ILUMIEN Lightlab Imaging, Inc. 4 Robbins Road Westford MA 01886 Optical coherence tomography software for medical imaging; computer software for use in medical diagnosis, namely, for use in measurement and assessment of measured physiological variables;Optical coherence computed tomography apparatus for medical imaging incorporating computer displays and computer monitors and controllers therefor used during medical imaging of an individual; computer monitors used in direct association with medical diagnostic apparatus for use in medical diagnostics and associated software for analyzing medical diagnostic data, all sold as a unit;
ILUMIEN OPTIS Lightlab Imaging, Inc. 4 Robbins Road Westford MA 01886 Optical coherence tomography software for medical imaging; computer software for use in medical diagnosis, namely, for use in measurement and assessment of measured physiological variables;Computer monitors used in direct association with medical diagnostic apparatus for use in medical diagnostics and associated software for analyzing medical diagnostic data, all sold as a unit;
OPTIS Lightlab Imaging, Inc. 4 Robbins Road Westford MA 01886 OPTICAL COHERENCE TOMOGRAPHY SOFTWARE FOR MEDICAL IMAGING; COMPUTER SOFTWARE FOR USE IN MEDICAL DIAGNOSIS, NAMELY, FOR USE IN MEASUREMENT AND ASSESSMENT OF MEASURED PHYSIOLOGICAL VARIABLES;In the statement line 12 INTRAVASCULAR PRESSURE SENSORS AND GUIDEWIRES is deleted.;COMPUTER MONITORS USED IN DIRECT ASSOCIATION WITH MEDICAL DIAGNOSTIC APPARATUS FOR USE IN MEDICAL DIAGNOSTICS AND ASSOCIATED SOFTWARE FOR ANALYZING MEDICAL DIAGNOSTIC DATA, ALL SOLD AS A UNIT [ ; INTRAVASCULAR PRESSURE SENSORS AND GUIDEWIRES ];
PCI OPTIMIZATION Lightlab Imaging, Inc. 4 Robbins Road Westford MA 01886 OPTICAL COHERENCE TOMOGRAPHY SOFTWARE FOR MEDICAL IMAGING; COMPUTER SOFTWARE FOR USE IN MEDICAL DIAGNOSIS, NAMELY, FOR USE IN MEASUREMENT AND ASSESSMENT OF MEASURED PHYSIOLOGICAL VARIABLES;CATHETERS USED IN MEDICAL IMAGING; OPTICAL COHERENCE COMPUTED TOMOGRAPHY APPARATUS FOR MEDICAL IMAGING INCORPORATING COMPUTER DISPLAYS AND COMPUTER MONITORS AND CONTROLLERS THEREFOR USED DURING MEDICAL IMAGING OF AN INDIVIDUAL; COMPUTER MONITORS USED IN DIRECT ASSOCIATION WITH MEDICAL DIAGNOSTIC APPARATUS FOR USE IN MEDICAL DIAGNOSTICS AND ASSOCIATED SOFTWARE FOR ANALYZING MEDICAL DIAGNOSTIC DATA, ALL SOLD AS A UNIT; INTRAVASCULAR PRESSURE SENSORS AND GUIDEWIRES;
 

Where the owner name is not linked, that owner no longer owns the brand

   
Technical Examples
  1. A high-speed optical delay generating method by a rotation reflector in optical coherence tomography, capable of providing a sectional picture with a sufficiently long depth-direction (Z direction) scanning distance, and an optical coherence tomography device therefor are provided. The device comprises a low-coherence light source (1), a half mirror (2) for splitting light from the low-coherence light source (1) into two, that is, into object light towards an object (A) to be examined and reference light, a light delay mechanism (3) for delaying the reference light by means of a rotation reflector (12), a fixed mirror (4) for reflecting/returning the reference light from the light delay mechanism (3), the half-mirror (2) for combining the object light returning from the object (A) to be examined with the reference light returning from the light delay mechanism, and a light detector (11) for detecting interference light including a heterodyne interference beat signal combined at the half mirror (2).